ASTM F449

ASTM F449

Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control
Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control
Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control
Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control
Standard Practice for Subsurface Installation of Corrugated Thermoplastic Tubing for Agricultural Drainage or Water Table Control
STANDARD PRACTICE FOR SUBSURFACE INSTALLATION OF CORRUGATED THERMOPLASTIC TUBING FOR AGRICULTURAL DRAINAGE OR WATER TABLE CONTROL
STANDARD PRACTICE FOR SUBSURFACE INSTALLATION OF CORRUGATED THERMOPLASTIC TUBING FOR AGRICULTURAL DRAINAGE OR WATER TABLE CONTROL
STANDARD PRACTICE FOR SUBSURFACE INSTALLATION OF CORRUGATED POLYETHYLENE PIPE FOR AGRICULTURAL DRAINAGE OR WATER TABLE CONTROL

: In stock

: ASTM

:

:

Publication Date
Format
$45.00

Publication Date: 02/15/2016 - Complete Document

Description :

This practice is recommended for and limited to gravity flow subsurface drainage systems or water table control, but not recommended for sanitary or storm sewer applications. Procedures are outlined to minimize pipe deflection or structural damage during and after the installation process. These installation procedures are in accordance with “flexible conduit” principles.

This practice applies to all agricultural subsurface drainage or water table control installations using Specification F667, F2648, or other plastic pipe.

The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

*A Summary of Changes section appears at the end of this standard

Document Type : Complete Document

Language : English

Page Count : 8

Publication Date : 02/15/2016

Revision : 16

Status : Current

Title : Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control

Publication Date: 09/10/2002 - Complete Document Changes Incorporated

Description :

This practice is recommended for and limited to gravity flow subsurface drainage systems or water table control, but not recommended for sanitary or storm sewer applications. Procedures are outlined to minimize pipe deflection or structural damage during and after the installation process. These installation procedures are in accordance with "flexible conduit" principles.

This practice applies to all agricultural subsurface drainage or water table control installations using Specification F405, F667 or other plastic pipe.

The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document Type : Complete Document

Language : English

Page Count : 7

Publication Date : 09/10/2002

Revision : 02

Status : Historical

Supplement : W/

Title : Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control

Publication Date: 09/10/2002 - Complete Document

Description :

This practice is recommended for and limited to gravity flow subsurface drainage systems or water table control, but not recommended for sanitary or storm sewer applications. Procedures are outlined to minimize pipe deflection or structural damage during and after the installation process. These installation procedures are in accordance with "flexible conduit" principles.

This practice applies to all agricultural subsurface drainage or water table control installations using Specification F 405, F 667 or other plastic pipe.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document Type : Complete Document

Language : English

Page Count : 7

Publication Date : 09/10/2002

Revision : 02

Status : Historical

Title : Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control

Publication Date: 05/10/1997 - Complete Document

Description :

1. Scope

1.1 This practice is recommended for and limited to gravity flow subsurface drainage systems or water table control, but not recommended for sanitary or storm sewer applications. Procedures are outlined to minimize pipe deflection or structural damage during and after the installation process. These installation procedures are in accordance with "flexible conduit" principles.

1.2 This practice applies to all agricultural subsurface drainage or water table control installations.

1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Document Type : Complete Document

Language : English

Page Count : 7

Publication Date : 05/10/1997

Revision : 97

Status : Historical

Title : Standard Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control

Publication Date: 01/01/1993 - Complete Document

Document Type : Complete Document

Language : English

Page Count : 6

Publication Date : 01/01/1993

Revision : 93

Status : Historical

Title : Standard Practice for Subsurface Installation of Corrugated Thermoplastic Tubing for Agricultural Drainage or Water Table Control

Publication Date: 03/11/1991 - Complete Document

Document Type : Complete Document

Language : English

Page Count : 6

Publication Date : 03/11/1991

Revision : 91

Status : Historical

Title : STANDARD PRACTICE FOR SUBSURFACE INSTALLATION OF CORRUGATED THERMOPLASTIC TUBING FOR AGRICULTURAL DRAINAGE OR WATER TABLE CONTROL

Publication Date: 12/27/1985 - Complete Document

Document Type : Complete Document

Language : English

Page Count : 9

Publication Date : 12/27/1985

Revision : 85

Status : Historical

Title : STANDARD PRACTICE FOR SUBSURFACE INSTALLATION OF CORRUGATED THERMOPLASTIC TUBING FOR AGRICULTURAL DRAINAGE OR WATER TABLE CONTROL

Publication Date: 01/01/1976 - Complete Document

Document Type : Complete Document

Page Count : 0

Publication Date : 01/01/1976

Revision : 76

Status : Historical

Title : STANDARD PRACTICE FOR SUBSURFACE INSTALLATION OF CORRUGATED POLYETHYLENE PIPE FOR AGRICULTURAL DRAINAGE OR WATER TABLE CONTROL